Browsing by Author "Jašíková, Darina"
Now showing 1 - 20 of 30
Results Per Page
Sort Options
- ItemAn experimental evaluation of convective heat transfer in multi-layered fibrous materials composed by different middle layer structures(SAGE PUBLICATIONS INC, 2455 TELLER RD, THOUSAND OAKS, CA 91320 USA, 2019-10) Xiong, Xiaoman; Venkataraman, Mohanapriya; Jašíková, Darina; Yang, Tao; Mishra, Rajesh; Militký, Jiří; Petrů, MichalIn this work, three types of multi-layered fibrous materials with different middle layer structures, including Struto nonwoven, Struto nonwoven with air pockets and Struto nonwoven with air pockets filled by aerogel particles, were prepared based on laser engraving technique and laminating method. A custom-built new device was fabricated to evaluate convective thermal behaviour of the multi-layered materials in cross flow. It was found that in cross flow the heat transfer coefficient of the multi-layered material with encapsulated aerogels is directly proportional to Reynolds number. There are considerable variances in heat transfer rates of the three structures at low airflow velocity (less than 10 m/s), but the values are very close at high airflow velocity. It is concluded that the air pockets and aerogels present in the multi-layered fibrous material have significant effect on convective thermal behaviour of the overall structure in cross flow. The finding is a new contribution to the field of aerogel-based fibrous materials as thermal insulators in building and industrial facilities.
- ItemCharakteristika pneumatického tryskového atomizéru(Technická Univerzita v Liberci, 2012) Lenc, Tadeáš; Jašíková, DarinaTato bakalářská práce se zabývá vizualizací, měřením a charakteristikou sprejů. Hlavním cílem je sestavit plně funkční atomizér. Seznámíme se s pojmem atomizace, rozebereme si, jak dochází k atomizaci a na jaké základní druhy se dělí. Velký důraz bude kladen na atomizaci vzduchovou. Objasníme si principy a možnosti konstrukce atomizérů, které později využijeme při návrhu našeho atomizéru. Dále se zabýváme možnostmi měření spreje, zaměříme se na metodu IPI. Provedeme měření našeho atomizéru a atomizéru průmyslově vyrobeného, abychom posléze mohli porovnat dosažené výsledky. V závěru práce pak vyhodnotíme náš atomizér a uvedeme si možné odvětví, kde by teoreticky bylo možné náš atomizér využívat.
- ItemEffect of Particle Image Velocimetry Setting Parameters on Local Velocity Measurements in an Agitated Vessel(WILEY-V C H VERLAG GMBH, POSTFACH 101161, 69451 WEINHEIM, GERMANY, 2019) Šulc, Radek; Ditl, Pavel; Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Kysela, BohušAlthough they are obtained under the same conditions, results on the flow field in an agitated vessel achieved using particle image velocimetry (PIV) may vary due to differences in the PIV conditions. The influence on turbulence characteristics of the main PIV setting parameters, i.e., PIV spatial resolution, sampling frequency, and recording time, was investigated. Tests were performed with three different liquids in a developed turbulent field for a Rushton turbine impeller using two-dimensional time-resolved PIV. To obtain the relevant velocity gradients, a minimum recording time is needed. No effect of sampling frequency was observed if the sampling frequency was higher than approximately 17 times the impeller frequency, which is about three times the impeller blade frequency.
- ItemExperimentální studium elektrostatického rozprašování a zvlákňování(Technická Univerzita v Liberci, 2011) Jašíková, DarinaTato disertační práce je zaměřena na experimentální studium a vizualizace elektrostatických procesů, tj. elektrostatického rozprašování a zvlákňování. Za tímto účelem jsou v práci navrženy a realizovány postupy, techniky i vlastní experimentální zařízení pro studium těchto elektrostatických procesů. Úkolem prováděných experimentů je ověření navržených metod a získání výsledků, které mohou napomoci k objasnění fyzikálních principů elektrostatického rozprašování a zvlákňování. Důležitou součástí disertační práce je i studium vlivu sekundárního proudění na elektrostatické procesy, které může najít uplatnění při realizaci technologií a průmyslových zařízení.
- ItemExperimentální studium elektrostatického rozprašování a zvlákňování(Technická Univerzita v Liberci, ) Jašíková, Darina
- ItemFlow of Newtonian and Non-Newtonian Fluid Through Pipe with Flexible Wall(2018) Šedivý, Dominik; Fialová, Simona; Jašíková, DarinaThis paper solves fluid-structure interaction between flexible wall and two types of fluid. Wall was considered as aorta and was described as hyperelastic material by 5-parameters Mooney-Rivlin model. Fluids and structure were set as incompressible. First fluid was Newtonian and has dynamic viscosity of the blood. Second was non-Newtonian and its viscosity was defined with Carreau rheology model. The aim of this paper is to show a comparison between Newtonian and non-Newtonian fluid flow in pliable vessel.
- ItemLaser generated plasma followed by shocks and increasing cavitation bubble in a mini-glass tube(Technická univerzita v Liberci, Česká republika, 2019) Schovanec, Petr; Garen, Walter; Koch, Sandra; Neu, Walter; Dančová, Petra; Jašíková, Darina; Kotek, Michal; Kopecký, VáclavBylo testováno mnoho typů mikrokapilár, čtvercových, kulatých a různých velikostí vnitřního průměru, ve kterých byla vytvořena kavitační bublina. Účelem těchto experimentů bylo sledovat rychlost rázové vlny těsně po počáteční kavitační bublině a odrazové vlny uvnitř i vně mikrokapilár. Hlavní metodou byla jiskra indukovaného limitu přehřátí kapaliny. Zde jsme použili metodu rozbití indukovanou laserem (LIB). Bylo popsáno nastavení kavitace, které ovlivňuje stabilitu a velikost bubliny. Pro snímání bublinek kavitace a rázové vlny jsme použili radiografické nastavení s kamerou. Byl pozorován časový vývoj rychlosti rázové vlny; rychlost počáteční rázové vlny uvnitř mikrokapiláry byla vyšší než rychlost rázu mimo mikrokapiláru.
- ItemLocal velocity scaling in upward flow to tooth impeller in a fully turbulent region(E D P SCIENCES, 17 AVE DU HOGGAR PARC D ACTIVITES COUTABOEUF BP 112, F-91944 CEDEX A, FRANCE, 2019) Šulc, Radek; Ditl, Pavel; Fořt, Ivan; Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Kysela, BohušThe hydrodynamics and flow field were measured in an agitated vessel using 2-D Time Resolved Particle Image Velocimetry (2-D TR PIV). The experiments were carried out in a fully baffled cylindrical flat bottom vessel 400 mm in inner diameter agitated by a tooth impeller 133 mm in diameter. Distilled water was used as the agitated liquid. The velocity fields were investigated in the upward flow to the impeller for three impeller rotation speeds- 300 rpm, 500 rpm and 700 rpm, corresponding to a Reynolds number in the range 94 000 < Re < 221 000. This means that fully-developed turbulent flow was reached. This Re range secures the fully-developed turbulent flow in an agitated liquid. In accordance with the theory of mixing, the dimensionless mean and fluctuation velocities in the measured directions were found to be constant and independent of the impeller Reynolds number. On the basis of the test results the spatial distributions of dimensionless velocities were calculated. The axial turbulence intensity was found to be in the majority in the range from 0.4 to 0.7, which corresponds to the middle level of turbulence intensity.
- ItemMatematický model clonky v závislosti diferenčního tlaku a průtoku pro neonatologické vysokofrekvenční ventilátory(Technická Univerzita v Liberci, 2014) Lamačová, Veronika; Jašíková, DarinaPráce se zabývá matematickou simulací průtoku v senzoru. Jako senzor průtoku slouží diferenční clona, která je určena k měření velikosti dechového objemu pacienta připojeného na vysokofrekvenční plicní ventilaci. Jsou určeny clony o různých délkách zúžení (0,5 mm, 1 mm, 3 mm), které je potřeba nejdřív vymodelovat v programu Autodesk Inventor. Následně je potřeba určit okrajové podmínky a poté je možné začít simulovat průtok clonou v programu Autodesk Simulation. Pro každý typ clony je určen průtokový profil a simulace jsou porovnány s experimentálním měřením. Práce také obsahuje informace o jednotlivých typech ventilací, převážně o vysokofrekvenční ventilaci používané v neonatologii. Dále rozebírá rozdíl mezi průtokem a prouděním a jejich měřením. V závěru práce jsou uvedeny programy, ve kterých je možné matematicky simulovat průtoky a proudění, jejich rozdíly a možnosti použití.
- ItemMatematický model clonky v závislosti diferenčního tlaku a průtoku pro neonatologické vysokofrekvenční ventilátory(Technická Univerzita v Liberci, 2014) Lamačová, Veronika; Jašíková, DarinaPráce se zabývá matematickou simulací průtoku v senzoru. Jako senzor průtoku slouží diferenční clona, která je určena k měření velikosti dechového objemu pacienta připojeného na vysokofrekvenční plicní ventilaci. Jsou určeny clony o různých délkách zúžení (0,5 mm, 1 mm, 3 mm), které je potřeba nejdřív vymodelovat v programu Autodesk Inventor. Následně je potřeba určit okrajové podmínky a poté je možné začít simulovat průtok clonou v programu Autodesk Simulation. Pro každý typ clony je určen průtokový profil a simulace jsou porovnány s experimentálním měřením. Práce také obsahuje informace o jednotlivých typech ventilací, převážně o vysokofrekvenční ventilaci používané v neonatologii. Dále rozebírá rozdíl mezi průtokem a prouděním a jejich měřením. V závěru práce jsou uvedeny programy, ve kterých je možné matematicky simulovat průtoky a proudění, jejich rozdíly a možnosti použití.
- ItemMeasurement of pulsatile flow characteristics in interaction with rigid and flexible wall(Technická univerzita v Liberci, ) Jašíková, Darina; Kotek, Michal; Malík, Michal; Primas, Jiří; Kopecký, Václav; Fakulta mechatroniky, informatiky a mezioborových studiíPulse flow was generated by a membrane pump. The nature of the pulsatile flow was measured with pressure sensors. We got information on the pressure development inside the circuit. Each phase of the pulse was evenly divided into 10 equal time slots. The individual slots were synchronized to the initial pressure change at 0.14Bar. The evaluation of the pressure measurement has already revealed the backward effect of the flexible wall. Especially when compared to glass rigid wall. Differences in pressures course are mostly significant in the peak width and lower stabilised pressure value. The flexible material absorbs part of pressure and expands its diameter. The liquid flow can be divided into four regimes: The first regime corresponds to pressure increase. The liquid flow is accelerated. The maximal fluid velocities reach 440 mm/s (Re 8800). The second regime is the highest point of pressure increase, where physically occurs the maximum membrane inclination, and closure of the pumps valves. At this point, the fluid stagnates, resulting in slowing down of the flow rate to 70 mm/s (Re 1400), and changing the characteristic velocity profile. This regime can be said as transient mode. The velocity profile is characterized with typical velocity decrease in the middle of cross section. This effect was found for both measurements – using rigid and flexible wall. The other phase of liquid acceleration can be observed in the third regime. Here, the liquid is fed with the pump. This acceleration last during the pressure decrease. This regime is characteristic with turbulent profile shape, and maximal flow velocity reach 260 mm/s (Re 5200). The fourth regime is observed since 6/5π period, when the pressure drop and starts to be stabilized. Here we can observe the liquid flow slowdown that is close to laminar profile shape. The maximal velocities in this regime are 35 mm/s (Re 700). There is an oscillation of a pressure, which leads to the formation of vortex structures near the wall. These structures are highlighted by the elasticity of the wall. The vortex structures were analysed using Proper Orthogonal Decomposition (POD). The most significant modes are for transient part of fluid flow and turbulent zone. The first 20 decomposition modes can be said as dominant. Here can be found vortex structures with kinetic energy of 10%. The nonstationary backward vortexes are developed close to the wall, as the fluid flow velocity is very small. The prevailing dominant effect on the fluid flow comes from the released kinetic energy from the relaxing flexible walls, especially in the fourth regime of pressure course. This effect is not significant for rigid walls. There were set an experimental setup for studying of cavitation base on Ventury tube. The fluid flow was analysed using high speed visualization methods in two interrogation areas in crosssection. The region of interest was focused on the swirling cavitation structure. The experiments run in 2018 were run in rigid wall. The fluid was also seeded with fluorescent particles for PIV measurement so the simple visualization was filled with fluid motion data’s. The investigated area was observed with synchronized two cameras recording parallel. The set of images were processed using supressing and dewarping algorithms. The experimental setup is prepared for the measurement on flexible wall and pulsatile flow.
- ItemMěření pohybu kapaliny a změn teploty v reálném modelu tepelného výměníku metodou PLIF(Technická Univerzita v Liberci, 2012) Hoffmann, Jakub; Jašíková, DarinaPředmětem této práce je kvalitativní a kvantitativní experimentální popis proudění kapaliny a vývoj teplotního pole uvnitř reálného modelu stratifikační nádoby tepelného výměníku. Při experimentální práci byly využity metody Particle image velocimetry a Planar laser induced fluorescence. Výsledky této práce poskytují cenné informace o chování kapaliny uvnitř nádoby, okrajových podmínkách i vznikajícím proudění uvnitř modelu potřebné pro správnost výpočtových modelů a simulací.
- ItemMěření vlivu výstupní hrany lopatky na vznik samobuzeného kmitání(Technická univerzita v Liberci, 2019) Kopecký, Václav; Kotek, Michal; Jašíková, Darina; Rudolf, Pavel
- ItemMixing of two immiscible phases measured by industrial electrical impedance tomography system(EDP SCIENCES S A, 17, AVE DU HOGGAR, PA COURTABOEUF, BP 112, F-91944 LES ULIS CEDEX A, FRANCE, 2019) Malík, Michal; Primas, Jiří; Kotek, Michal; Jašíková, Darina; Kopecký, VáclavThe mixing of two immiscible phases is a process commonly seen in many industrial applications. Whether it is desirable (e.g. mixing of ingredients in chemical or food industry) or undesirable (e.g. sediments or contaminants in water purification) process, it has to be taken into consideration and a detailed description would be beneficial to any end product. This paper deals with a method for observing the volume ratio of two immiscible phases from the state of total separation to the state of a homogenous mixture using industrial Electrical Impedance Tomography (EIT) system ITS p2+. This paper also shows a great advantage in combining the EIT measuring method with a theoretically derived formula. It is used to calculate the concentration of a non-conductive phase in the final mixture using the initial and final conductivity values. The authors were also able to show a possibility to successfully use the formula in situations, where the initial conditions for it are not fully met.
- ItemNávrh softwaru pro vyhodnocení dynamického kontaktního úhlu(Technická Univerzita v Liberci, 2014) Liederhaus, Matěj; Jašíková, DarinaDiplomová práce se zabývá rešerší na téma určování povrchové energie a měření kontaktního úhlu. V teoretické části jsou popsány základní pojmy a vztahy popisující smáčení pevných povrchů. Dále jsou zde popsány nejběžnější metody určování povrchové energie a kontaktního úhlu. Zmíněny jsou také příklady použití hydrofobních povrchů. Závěr teoretické části je věnován popisu metody použité k získání obrazového materiálu pro experimentální studii interakce kapaliny s pevnou fází. V praktické části je vylíčen postup sestavování programu na vyhodnocování dynamických kontaktních úhlů. Jsou zde uvedeny použité i zavrhnuté postupy k docílení jednotlivých dílčích výsledků včetně argumentů, které vedly k patřičným úvahám. V závěru praktické části jsou představeny výsledky testovacího měření na reálném obrazovém materiálu a porovnání získaných výsledků.
- ItemNávrh softwaru pro vyhodnocování účinnosti filtrace nanovlákenné vrstvy(Technická Univerzita v Liberci, 2011) Kumstýř, Adam; Jašíková, DarinaHlavním tématem této práce je popis a seznámení s nanomateriály, jejich výrobou, vlastnostmi a přínosem pro moderní společnost. Jsou zde zmíněna nanovlákna, historický vývoj jejich tvorby a spjatost s Technickou univerzitou Liberec, zejména zásadní průlom v průmyslové výrobě nanovlákenných vrstev. Dále je zde uvedeno použití nanovlákenných materiálů v oblasti filtrů, a je zde objasněna problematika testování filtračních materiálů. Praktická část pak pojednává o konkrétním příkladu testování filtrační aparatury a návrhu softwaru, který je při testu použit. Cílem této bakalářské práce bylo vytvořit funkční software umožňující načítání obrazů zaznamenaných kamerou, jejich vyhodnocení a zpracování do výsledků. Výsledek je pak zobrazen formou série 2D grafů přímo v prostředí Borland Delphi.
- ItemPočítačem řízený posun vzorku textilního materiáluJašíková, Darina
- ItemPočítačem řízený posun vzorku textilního materiálu(Technická Univerzita v Liberci, 2006) Jašíková, Darina; Kretschmerová, Lenka
- ItemStudie procesu stratifikace v reálném modelu tepelného výměníku(Technická Univerzita v Liberci, 2014) Hoffmann, Jakub; Jašíková, DarinaCílem diplomové práce je kvalitativní a kvantitativní experimentální popis časového vývoje proudění kapaliny v reálném modelu stratifikační nádoby tepelného výměníku pomocí měřeních na reálném modelu a pomocí simulací na PC. K experimentální studii jsou využity měřicí systémy PIV a pLIF. Výsledky měření poskytnou informace o chování proudění, okrajových podmínkách a vznikajícím proudění uvnitř modelu nádrže. Experimentální data jsou využita k verifikaci výsledků matematických modelů a simulací a následně s těmito daty porovnána.
- ItemThe Minimum Recording Time for PIV Measurements in a Vessel Agitated by a High-Shear Tooth Impeller(MAIK NAUKA/INTERPERIODICA/SPRINGER, 233 SPRING ST, NEW YORK, NY 10013-1578 USA, 2020-03) Šulc, Radek; Ditl, Pavel; Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Kysela, BohušThe flow field in a mechanically agitated vessel has often been investigated by Particle Image Velocimetry (PIV). In published studies, the recording time ranges between tenths of seconds and units of seconds. The question arises: What is the minimum recording time that is needed to obtain relevant data? Our study was aimed at determining the minimum recording time that is required to get consistent velocity field results, using the PIV technique, in a vessel agitated by a high-shear tooth impeller within the impeller flow discharge zone. Our results help to adjust PIV experimental conditions that guarantee correct velocity data. The tests were performed in a fully-baffled cylindrical flat-bottom vessel 400 mm in inner diameter agitated by a tooth impeller 133 mm in diameter, with three different liquids, using 2-D Time-Resolved PIV in the impeller Reynolds number range from 68 000 to 221 000. A statistical analysis of the radial and axial components of the mean and fluctuation velocities measured in the impeller discharge flow showed that the dimensionless minimum recording time is independent of the impeller Reynolds number. The value is N.t(Rmin) = 62 for the mean radial velocity and fluctuation velocities in both the radial direction and the axial direction, while a longer measuring time, N.t(Rmin) = 174, is required to obtain the consistent mean axial velocity for +/- 2% volatility. The dimensionless criterion N.t(Rmin) = const is recommended as the scale-up rule for an estimate of the minimum recording time.