PLC Mitsubishi jako náhrada fyzikálního modelu
Title Alternative:PLC Mitsubishi as physical model substitution
dc.contributor.advisor | Hernych, Miloš | |
dc.contributor.author | Pacák, Jiří | |
dc.date | 2009 | |
dc.date.accessioned | 2013-12-20 | |
dc.date.available | 2013-12-20 | |
dc.date.committed | 1899-12-30 | |
dc.date.defense | 2009-06-24 | |
dc.date.issued | 2013-12-20 | |
dc.date.submitted | 2008-10-31 | |
dc.degree.level | bc | cs |
dc.description | katedra: MTI; přílohy: 1 CD ROM; rozsah: 62 s.,18 s příloh | cs |
dc.description.abstract | Cílem bakalářské práce je vytvoření programu pro virtuální modely v prostředí GX Developer určeném pro PLC Mitsubishi, včetně vizualizace v operátorském panelu. Pro demonstraci naprogramovaných modelů sestavit z dostupných prvků zkušební panel, zapojit jednotlivé moduly a nakonfigurovat PLC systém. Na zkušebním panelu je použit systém PLC Mitsubishi řady Q obsahující dvě CPU jednotky, operační panel, vstupní a výstupní moduly. Systém je nakonfigurován tak, že každá CPU jednotka řídí jemu přiřazené moduly a chová se jako samostatný PLC systém. CPU jednotka č.1 řeší úlohu virtuálního modelu a je napojena na operační panel, kde zobrazuje činnost modelu. CPU jednotka č.2 je určena pro naprogramování chodu virtuálního modelu a je propojena s CPU jednotkou č.1 vodiči přes I/O moduly. Modely naprogramované v operátorském panelu zobrazují chování fyzikálního modelu a činné prvky obsahují popis adres proměnných pro použití v ovládacím programu. Virtuální modely jsou popsány v metodické příručce s popisem instrukcí k použití v ovládacím programu modelu a vývojovým diagramem popisující činnost modelu. | cs |
dc.description.abstract | The aim of this bachelor thesis is to create a program for virtual models in the GX Developer environment which is designed for PLC Mitsubishi, including visualization in the operating panel. Also, out of available elements to assemble a panel, connect and configuration modules for model demonstration The system PLC Mitsubishi of the Q series containing two CPU units, operating panel, input and output modules is used in the experimental panel. The system is configured in a way that each CPU unit controls modules assigned to it and behaves as an independent PLC system. CPU unit number 1 handles the task of the virtual model and is connected to the operating panel where is displays the model´s activity. CPU unit number 2 is designed to program the operating of the virtual model and is interconnected with the CPU unit number 1 with the help of wires through I/O modules. Models programmed in the operating panel display the performance of the physical model. Virtual models are described in a methodological guidebook with the description of instructions to use in the controlling program of the model and in a flowchart describing the activity of the model. | en |
dc.format | text | |
dc.identifier.uri | https://dspace.tul.cz/handle/15240/752 | |
dc.language.iso | cs | |
dc.publisher | Technická Univerzita v Liberci | cs |
dc.subject | plc | cs |
dc.subject | mitsubishi | cs |
dc.subject | hmi | cs |
dc.subject | operátorský panel | cs |
dc.subject | virtuální model | cs |
dc.subject | plc | en |
dc.subject | mitsubishi | en |
dc.subject | hmi | en |
dc.subject | operating panel | en |
dc.subject | virtual model | en |
dc.subject.verbis | computer modeling | en |
dc.title | PLC Mitsubishi jako náhrada fyzikálního modelu | cs |
dc.title.alternative | PLC Mitsubishi as physical model substitution | en |
dc.type | Thesis | |
local.department | MTI | cs |
local.identifier.stag | 16378 | |
local.identifier.verbis | 396963 | |
local.note.administrators | oprava_A | |
local.verbis.aktualizace | 2019-10-05 06:20:56 | cs |
local.verbis.studijniprogram | MTI Elektrotechnika a informatika/Informatika a logistika | cs |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- bc_16378.pdf
- Size:
- 2.42 MB
- Format:
- Adobe Portable Document Format
- Description:
- kvalifikační práce