Computer estimation of dissociation constants. Part 6. Diagnostics in regression analysis of absorbance-pH curve

Loading...
Thumbnail Image
Date
1994
Journal Title
Journal ISSN
Volume Title
Publisher
Springer-Verlag
Abstract
Nonlinear regression program DCMINOPT is introduced for numerical analysis of a set of {A, pH} data expressing a dependence of absorbance of a mixture of variously protonated light-absorbing species L, LH,..., LHR on pH. Efficiency of the program has been examined on simulated A-pH data corrupted with artificial (generated) errors namely for a case of closely overlapping protonation equilibria. An accuracy and precision of parameters estimates have been examined and compared with those determined by another three standard algorithms DCFIT, DCMINUIT and PSEQUAD. Goodness-of-fit test brings various regression diagnostics, 3D-plots and statistical measures enabling to test and prove a reliability of a regression process and accuracy and precision of parameter estimates. © 1993 Springer-Verlag.
Description
Subject(s)
accuracy and precision of pKa and {Mathematical expression}, closely overlapping equilibria, consecutive protonation of LHr, dissociation constants pKa, goodness-of-fit test, molar absorption coefficients {Mathematical expression}, nonlinear regression of A-pH curve, regression diagnostics, reliability of pKa estimation
Citation
ISSN
0026-3672
ISBN
Collections