Browsing by Author "Vojta, Lukáš"
Now showing 1 - 5 of 5
Results Per Page
Sort Options
- ItemIntroductory Numerical Study on Supersonic Ejector Working with R32(E D P SCIENCES, 17 AVE DU HOGGAR PARC D ACTIVITES COUTABOEUF BP 112, F-91944 CEDEX A, FRANCE, 2019) Vojta, Lukáš; Kracík, Jan; Dvořák, VáclavNowadays, there is an increasing demand for devices which work efficiently with the smallest possible consumption of energy. In this regard, incorporating ejectors seems to be an interesting choice. This paper describes the numerical analysis of the flow in a supersonic ejector working with R32 (difluoromethane) as the working fluid. The ejector geometry under investigation in this paper has already been experimentally analysed, however, air was used as the working fluid. Therefore, this paper deals with a numerical analysis of the same geometry but with a different working fluid. Furthermore, the design of the ejector enabled the adjustment of a particular distance of the motive nozzle from the beginning of the mixing chamber, i.e. the nozzle exit position (NXP). This work examines the ejector numerically for eleven values of back-pressure with the NXP of two millimetres; consequently, the performance line of the ejector with fixed boundary conditions at both inlets was obtained. Finally, the obtained results are discussed and some recommendations for future research have been made.
- ItemMeasurement and calculating of supersonic ejectors(E D P SCIENCES, 17 AVE DU HOGGAR PARC D ACTIVITES COUTABOEUF BP 112, F-91944 CEDEX A, FRANCE, 2019) Vojta, Lukáš; Dvořák, VáclavThis paper deals with numerical and experimental investigation of the flow in an air to air supersonic ejector with constant area mixing chamber. The mixing chamber of previous ejector was completely repaired since a scratch from previous turning had been found. As a result, a new geometry of the mixing chamber was created. Several measurements were conducted with different nozzle position (NP): 1 mm, 2 mm and 3 mm. Furthermore, for a given NP, two different values of stagnation pressure of 200 kPa and 300 kPa at the primary air inlet were investigated in more detail. All numerical simulations were performed in the ANSYS Fluent software. It was found that the influence of the position of the nozzle influences the ejection factor only to a certain extent. For the other parameters of the ejector is also a need to find the optimum position of the nozzle. Repair of the mixing chamber has contributed to reduce the pressure difference at the wall of the mixing chamber.
- ItemMěření a výpočet supersonických ejektorůVojta, Lukáš; S16000018; Dvořák Václav, doc. Ing. Ph.D. : 55439; Kracík Jan, Ing. Konzultant : 64357Diplomová práce se zabývá analytickým, numerickým a experimentálním studiem proudění vzduchu v nadzvukovém ejektoru, který je umístěn v laboratoři katedry energetických zařízení na Technické Univerzitě v Liberci. Tento ejektor prošel kompletní opravou směšovací komory, kde došlo ke změně geometrie. S takto upravenou geometrií bylo provedeno několik měření, při nastaveních vzdáleností výstupní části trysky od směšovací komory, a to 1 mm, 2 mm a 3 mm. Dále pak při hodnotách hnacího tlaku 200kPa a 300kPa.
- ItemMěření hemodynamických deskriptorů sedící osoby(Technická Univerzita v Liberci, 2016) Vojta, Lukáš; Cirkl, DavidHlavním cílem bakalářské práce bylo zjistit možnosti využití vybraných biosignálů k monitorování hemodynamiky cévního systému dolních končetin dlouhodobě sedící osoby. Na základě teoretického rozboru problematiky, technických možností laboratoře a realizací dvou případových studií byla jako hlavní deskriptor vybrána variabilita srdeční frekvence (HRV). V rámci pilotní studie (N = 6) nebyl během prvních dvou hodin u sedících osob zjištěn statisticky významný rozdíl ve změnách HRV. Taktéž se nepodařilo jednoznačně prokázat vliv proměnlivé tuhosti sedáku na tento deskriptor. Výsledky provedených experimentů mohou sloužit jako východiska pro navazující studie v této problematice. V nich by bylo vhodné se zaměřit na využití monitorování krevního tlaku, pletysmografii a dopplerovskou echokardiografii.
- ItemMěření hemodynamických deskriptorů sedící osobyVojta, Lukáš