Browsing by Author "Kopecký, Václav"
Now showing 1 - 20 of 26
Results Per Page
Sort Options
- ItemAplikace laserové dopplerovské anemometrie na měření proudových polí vzduchového prohozu tryskového tkacího stroje(Technická Univerzita v Liberci, ) Kopecký, Václav
- ItemCalculation and measurement of a neutral air flow velocity impacting a high voltage capacitor with asymmetrical electrodes(Amer Inst Physics, 2014) Malík, Michal; Primas, Jiří; Kopecký, Václav; Svoboda, MiroslavThis paper deals with the effects surrounding phenomenon of a mechanical force generated on a high voltage asymmetrical capacitor (the so called Biefeld-Brown effect). A method to measure this force is described and a formula to calculate its value is also given. Based on this the authors derive a formula characterising the neutral air flow velocity impacting an asymmetrical capacitor connected to high voltage. This air flow under normal circumstances lessens the generated force. In the following part this velocity is measured using Particle Image Velocimetry measuring technique and the results of the theoretically calculated velocity and the experimentally measured value are compared. The authors found a good agreement between the results of both approaches. (C) 2014 Author(s).
- ItemCenová strategie firmyKopecký, Václav
- ItemEffect of Particle Image Velocimetry Setting Parameters on Local Velocity Measurements in an Agitated Vessel(WILEY-V C H VERLAG GMBH, POSTFACH 101161, 69451 WEINHEIM, GERMANY, 2019) Šulc, Radek; Ditl, Pavel; Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Kysela, BohušAlthough they are obtained under the same conditions, results on the flow field in an agitated vessel achieved using particle image velocimetry (PIV) may vary due to differences in the PIV conditions. The influence on turbulence characteristics of the main PIV setting parameters, i.e., PIV spatial resolution, sampling frequency, and recording time, was investigated. Tests were performed with three different liquids in a developed turbulent field for a Rushton turbine impeller using two-dimensional time-resolved PIV. To obtain the relevant velocity gradients, a minimum recording time is needed. No effect of sampling frequency was observed if the sampling frequency was higher than approximately 17 times the impeller frequency, which is about three times the impeller blade frequency.
- ItemExperimentální výzkum nestacionárních proudových polí tkacích trysek(Technická Univerzita v Liberci, 2007) Janoušek, Michal; Kopecký, VáclavDiplomová práce se zabývá experimentálním výzkumem nestacionárních proudových polí tkacích trysek. Pro měření je využita moderní anemometrická metoda PIV (Partical Image Velocimetry) a okrajově také LDA (Laser Doppler Anemometry). Pro možnost porovnání naměřených dat byly provedeny simulace v prostředí Fluent. Na základě naměřených dat je podrobně popsáno chování proudu ve stacionárním režimu a také vznik, vývoj a charakter proudu v pulzním režimu (rozběh, ustálení, doznívání). Práce se také zabývá experimentem při zachycení letícího útku a stanovením rychlosti jeho pohybu.
- ItemExperimentální výzkum syntetizovaných proudů laserovými anemometriemi(Technická Univerzita v Liberci, 2013-12-20) Gruncl, Michal; Kopecký, VáclavCílem diplomové práce je experimentální výzkum syntetizovaných proudů laserovými anemometriemi. Práce popisuje výběr metody PIV pro měření nestacionárních proudových polí, její princip a limity, vlastnosti a možné aplikace syntetizovaných proudů. Dále zkoumá možnosti aktivního řízení toku tekutiny syntetizovanými proudy v ústí trysky.
- ItemFotopolymerní záznamová média pro použití v holografické interferometrii(Technická Univerzita v Liberci, 2009) Lédl, Vít; Kopecký, Václav
- ItemLaser generated plasma followed by shocks and increasing cavitation bubble in a mini-glass tube(Technická univerzita v Liberci, Česká republika, 2019) Schovanec, Petr; Garen, Walter; Koch, Sandra; Neu, Walter; Dančová, Petra; Jašíková, Darina; Kotek, Michal; Kopecký, VáclavBylo testováno mnoho typů mikrokapilár, čtvercových, kulatých a různých velikostí vnitřního průměru, ve kterých byla vytvořena kavitační bublina. Účelem těchto experimentů bylo sledovat rychlost rázové vlny těsně po počáteční kavitační bublině a odrazové vlny uvnitř i vně mikrokapilár. Hlavní metodou byla jiskra indukovaného limitu přehřátí kapaliny. Zde jsme použili metodu rozbití indukovanou laserem (LIB). Bylo popsáno nastavení kavitace, které ovlivňuje stabilitu a velikost bubliny. Pro snímání bublinek kavitace a rázové vlny jsme použili radiografické nastavení s kamerou. Byl pozorován časový vývoj rychlosti rázové vlny; rychlost počáteční rázové vlny uvnitř mikrokapiláry byla vyšší než rychlost rázu mimo mikrokapiláru.
- ItemLocal velocity scaling in upward flow to tooth impeller in a fully turbulent region(E D P SCIENCES, 17 AVE DU HOGGAR PARC D ACTIVITES COUTABOEUF BP 112, F-91944 CEDEX A, FRANCE, 2019) Šulc, Radek; Ditl, Pavel; Fořt, Ivan; Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Kysela, BohušThe hydrodynamics and flow field were measured in an agitated vessel using 2-D Time Resolved Particle Image Velocimetry (2-D TR PIV). The experiments were carried out in a fully baffled cylindrical flat bottom vessel 400 mm in inner diameter agitated by a tooth impeller 133 mm in diameter. Distilled water was used as the agitated liquid. The velocity fields were investigated in the upward flow to the impeller for three impeller rotation speeds- 300 rpm, 500 rpm and 700 rpm, corresponding to a Reynolds number in the range 94 000 < Re < 221 000. This means that fully-developed turbulent flow was reached. This Re range secures the fully-developed turbulent flow in an agitated liquid. In accordance with the theory of mixing, the dimensionless mean and fluctuation velocities in the measured directions were found to be constant and independent of the impeller Reynolds number. On the basis of the test results the spatial distributions of dimensionless velocities were calculated. The axial turbulence intensity was found to be in the majority in the range from 0.4 to 0.7, which corresponds to the middle level of turbulence intensity.
- ItemMarketingová studie pivovaru Hols ve Vratislavicích a.s.Kopecký, Václav
- ItemMeasurement of pulsatile flow characteristics in interaction with rigid and flexible wall(Technická univerzita v Liberci, ) Jašíková, Darina; Kotek, Michal; Malík, Michal; Primas, Jiří; Kopecký, Václav; Fakulta mechatroniky, informatiky a mezioborových studiíPulse flow was generated by a membrane pump. The nature of the pulsatile flow was measured with pressure sensors. We got information on the pressure development inside the circuit. Each phase of the pulse was evenly divided into 10 equal time slots. The individual slots were synchronized to the initial pressure change at 0.14Bar. The evaluation of the pressure measurement has already revealed the backward effect of the flexible wall. Especially when compared to glass rigid wall. Differences in pressures course are mostly significant in the peak width and lower stabilised pressure value. The flexible material absorbs part of pressure and expands its diameter. The liquid flow can be divided into four regimes: The first regime corresponds to pressure increase. The liquid flow is accelerated. The maximal fluid velocities reach 440 mm/s (Re 8800). The second regime is the highest point of pressure increase, where physically occurs the maximum membrane inclination, and closure of the pumps valves. At this point, the fluid stagnates, resulting in slowing down of the flow rate to 70 mm/s (Re 1400), and changing the characteristic velocity profile. This regime can be said as transient mode. The velocity profile is characterized with typical velocity decrease in the middle of cross section. This effect was found for both measurements – using rigid and flexible wall. The other phase of liquid acceleration can be observed in the third regime. Here, the liquid is fed with the pump. This acceleration last during the pressure decrease. This regime is characteristic with turbulent profile shape, and maximal flow velocity reach 260 mm/s (Re 5200). The fourth regime is observed since 6/5π period, when the pressure drop and starts to be stabilized. Here we can observe the liquid flow slowdown that is close to laminar profile shape. The maximal velocities in this regime are 35 mm/s (Re 700). There is an oscillation of a pressure, which leads to the formation of vortex structures near the wall. These structures are highlighted by the elasticity of the wall. The vortex structures were analysed using Proper Orthogonal Decomposition (POD). The most significant modes are for transient part of fluid flow and turbulent zone. The first 20 decomposition modes can be said as dominant. Here can be found vortex structures with kinetic energy of 10%. The nonstationary backward vortexes are developed close to the wall, as the fluid flow velocity is very small. The prevailing dominant effect on the fluid flow comes from the released kinetic energy from the relaxing flexible walls, especially in the fourth regime of pressure course. This effect is not significant for rigid walls. There were set an experimental setup for studying of cavitation base on Ventury tube. The fluid flow was analysed using high speed visualization methods in two interrogation areas in crosssection. The region of interest was focused on the swirling cavitation structure. The experiments run in 2018 were run in rigid wall. The fluid was also seeded with fluorescent particles for PIV measurement so the simple visualization was filled with fluid motion data’s. The investigated area was observed with synchronized two cameras recording parallel. The set of images were processed using supressing and dewarping algorithms. The experimental setup is prepared for the measurement on flexible wall and pulsatile flow.
- ItemMěření vlivu výstupní hrany lopatky na vznik samobuzeného kmitání(Technická univerzita v Liberci, 2019) Kopecký, Václav; Kotek, Michal; Jašíková, Darina; Rudolf, Pavel
- Item
- ItemMixing of two immiscible phases measured by industrial electrical impedance tomography system(EDP SCIENCES S A, 17, AVE DU HOGGAR, PA COURTABOEUF, BP 112, F-91944 LES ULIS CEDEX A, FRANCE, 2019) Malík, Michal; Primas, Jiří; Kotek, Michal; Jašíková, Darina; Kopecký, VáclavThe mixing of two immiscible phases is a process commonly seen in many industrial applications. Whether it is desirable (e.g. mixing of ingredients in chemical or food industry) or undesirable (e.g. sediments or contaminants in water purification) process, it has to be taken into consideration and a detailed description would be beneficial to any end product. This paper deals with a method for observing the volume ratio of two immiscible phases from the state of total separation to the state of a homogenous mixture using industrial Electrical Impedance Tomography (EIT) system ITS p2+. This paper also shows a great advantage in combining the EIT measuring method with a theoretically derived formula. It is used to calculate the concentration of a non-conductive phase in the final mixture using the initial and final conductivity values. The authors were also able to show a possibility to successfully use the formula in situations, where the initial conditions for it are not fully met.
- ItemModelování proudění hydraulickým prvkem s pružnou stěnou a případnou kavitací - FSI analýza(Technická univerzita v Liberci, ) Kozubková, Milada; Blejchař, Tomáš; Fialová, Simona; Kopecký, Václav; Fakulta mechatroniky, informatiky a mezioborových studií
- ItemSebehodnocení útvaru Policie ČR na základě modelu exelence EFQM(Technická Univerzita v Liberci, 2007) Hrabánek, Tomáš; Kopecký, Václav
- ItemThe Minimum Recording Time for PIV Measurements in a Vessel Agitated by a High-Shear Tooth Impeller(MAIK NAUKA/INTERPERIODICA/SPRINGER, 233 SPRING ST, NEW YORK, NY 10013-1578 USA, 2020-03) Šulc, Radek; Ditl, Pavel; Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Kysela, BohušThe flow field in a mechanically agitated vessel has often been investigated by Particle Image Velocimetry (PIV). In published studies, the recording time ranges between tenths of seconds and units of seconds. The question arises: What is the minimum recording time that is needed to obtain relevant data? Our study was aimed at determining the minimum recording time that is required to get consistent velocity field results, using the PIV technique, in a vessel agitated by a high-shear tooth impeller within the impeller flow discharge zone. Our results help to adjust PIV experimental conditions that guarantee correct velocity data. The tests were performed in a fully-baffled cylindrical flat-bottom vessel 400 mm in inner diameter agitated by a tooth impeller 133 mm in diameter, with three different liquids, using 2-D Time-Resolved PIV in the impeller Reynolds number range from 68 000 to 221 000. A statistical analysis of the radial and axial components of the mean and fluctuation velocities measured in the impeller discharge flow showed that the dimensionless minimum recording time is independent of the impeller Reynolds number. The value is N.t(Rmin) = 62 for the mean radial velocity and fluctuation velocities in both the radial direction and the axial direction, while a longer measuring time, N.t(Rmin) = 174, is required to obtain the consistent mean axial velocity for +/- 2% volatility. The dimensionless criterion N.t(Rmin) = const is recommended as the scale-up rule for an estimate of the minimum recording time.
- ItemVerifikační stand pro měření rychlostních polí systémem PIV(Technická univerzita v Liberci, 2003) Kopecký, Václav; Výzkumné centrum - TextilNa počátku tohoto roku byl sestaven měřící systém PIV - Particle Image Vlocimetry. Nákup proběhl ve dvou etapách v letech 2001-2002. PIV je moderní výkonná měřící metoda pracující na opto-elektronickém principu a využívající laserové světlo, Oblastí jejího nasazení je experimentální mechanika tekutin. Jedná se o bezdotykovou metodu měřící rychlost media pomocí mikroskopických částic v něm rozptýlených. Měření je lineami v celém rozsahu zkoumaných rychlostí a výsledky nejsou závislé na okolních vlivech, jako je teplota, tlak, vlhkost atd. Jediným požadavkem je transparentnost měřené tekutiny a optický přístup do měřeného prostoru. Praktický rozvoj metody PIV byl vázán na dostupnost použitelných výkonných pulsních laserů a zároveň na existenci dostatečně výkonné výpočetní techniky, elektroniky a fotoniky. To zapříčinilo, že hlavní rozvoj metody PIV se uplatňuje až po roce 1995. Z obecného hlediska představuje tato technika interdisciplinární téma zahrnující např. fyzikální principy, laserovou techniku, optiku, elektroniku, fotoniku, matematické algoritmy a analýzu signálů a dat. Uvedená témata nezůstávají tzv. „skrytá", ale jejich pochopení se zásadním způsobem promítá do optimální přípravy experimentu, vlastního měření a správné interpretace naměřených výsledků. V důsledku toho klade zvládnutí této metody značné nároky na komplexní znalosti a experimentální zkušenosti, jak experimentátorů, tak odborníků v problematice mechaniky tekutin, kteří obvykle formulují a zadávají měřené úlohy. Z výše uvedených důvodů byl první krok zprovoznění PIV systému zaměřen na ověření jeho funkčnosti. Za tímto účelem byl navržen a realizován demonstrační stand pro verifikační měření proudových polí metodou PIV. Na základě vhodně zvolené demonstrační úlohy a rozboru výsledků měření byly pak ověřovány funkčnost a aplikační možnosti měřícího systému. Souhrnné informace jsou uvedeny v této zprávě, podrobnější údaje lze nalézt v diplomové práci [4].
- ItemVliv teploty a vlhkosti na tepelný odpor spacích pytlů(2022-05-13) Kopecký, Václav
- ItemVyužití hydrofobních a olejofobních povrchů při interakci s kapalinami(2019-01-31) Jašíková, Darina; Kotek, Michal; Kopecký, Václav; Gašić, M.; Mikulášek, J.; Fakulta mechatroniky, informatiky a mezioborových studií