An on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography: A case study on the determination of bisphenol A in environmental water samples

dc.contributor.authorHakova Martinacs
dc.contributor.authorChocholousova Havlikova Luciecs
dc.contributor.authorChvojka Jiřícs
dc.contributor.authorSolich Petrcs
dc.contributor.authoršatinský Daliborcs
dc.date.accessioned2018-09-25T12:17:05Z
dc.date.available2018-09-25T12:17:05Z
dc.date.issued2018cs
dc.description.abstractPolyamide 6 nanofiber polymers were used as modern sorbents for on-line solid phase extraction (SPE) coupled with liquid chromatography. The on-line SPE system was tested for the determination of bisphenol A in river water samples. Polyamide nanofibers were prepared using needleless electrospinning, inserted into a mini-column cartridge (5 × 4.6 mm) and coupled with HPLC. The effect of column packing and the amount of polyamide 6 on extraction efficiency was tested and the packing process was optimized. The proposed method was performed using a 50-µL sample injection followed by an on-line nanofibrous extraction procedure. The influence of the washing mobile phase on the retention of bisphenol A during the extraction procedure was evaluated. Ascentis® Express C18 (10 cm × 4.6 mm) core-shell column was used as an analytical column. Fluorescence detection wavelengths (λex = 225 nm and λem = 320 nm) were used for identification and quantification of Bisphenol A in river waters. The linearity was tested in the range from 2 to 500 µg L−1 (using nine calibration points). The limits of detection and quantification were 0.6 and 2 µg L−1, respectively. The developed method was successfully used for the determination of bisphenol A in various samples of river waters in the Czech Republic (The Ohře, Labe, Nisa, Úpa, and Opava Rivers).en
dc.format.extent6cs
dc.identifier.doi10.1016/j.talanta.2017.08.098
dc.identifier.issn0039-9140cs
dc.identifier.urihttps://dspace.tul.cz/handle/15240/31616
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0039914017309050?via%3Dihub
dc.language.isoengcs
dc.relation.ispartofseries1cs
dc.relation.urihttps://www.sciencedirect.com/science/article/pii/S0039914017309050?via=ihubcs
dc.subjectNanofiber polymerscs
dc.subjectOn-line SPEcs
dc.subjectNanofibrous extractioncs
dc.subjectUHPLC Fluorimetrycs
dc.subjectBisphenol Acs
dc.titleAn on-line coupling of nanofibrous extraction with column-switching high performance liquid chromatography: A case study on the determination of bisphenol A in environmental water samplesen
local.citation.epage141-146cs
local.citation.spage141-146cs
local.identifier.publikace5080
local.identifier.wok416615500021en
local.relation.issue1cs
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
An on-line coupling of nanofibrous.pdf
Size:
537.98 KB
Format:
Adobe Portable Document Format
Description:
článek
Collections