The MPGD-based photon detectors for the upgrade of COMPASS RICH-1
dc.contributor.author | Šulc Miroslav | cs |
dc.contributor.author | Steiger Kateřina | cs |
dc.contributor.author | Steiger Lukáš | cs |
dc.contributor.organization | the COMPASS | |
dc.date.accessioned | 2018-09-25T12:18:27Z | |
dc.date.available | 2018-09-25T12:18:27Z | |
dc.date.issued | 2017-01-01 | cs |
dc.description.abstract | The RICH-1 Detector of the COMPASS experiment at CERN SPS has undergone an important upgrade for the 2016 physics run. Four new photon detectors, based on Micro Pattern Gaseous Detector technology and covering a total active area larger than 1.2 m2 have replaced the previously used MWPC-based photon detectors. The upgrade answers the challenging efficiency and stability quest for the new phase of the COMPASS spectrometer physics programme. The new detector architecture consists in a hybrid MPGD combination of two Thick Gas Electron Multipliers and a MicroMegas stage. Signals, extracted from the anode pad by capacitive coupling, are read-out by analog F-E based on the APV25 chip. The main aspects of the COMPASS RICH-1 photon detectors upgrade are presented focussing on detector design, engineering aspects, mass production, the quality assessment and assembly challenges of the MPGD components. The status of the detector commissioning is also presented. | |
dc.format.extent | 5 | cs |
dc.identifier.doi | 10.1016/j.nima.2017.02.013 | |
dc.identifier.issn | 0168-9002 | cs |
dc.identifier.uri | https://dspace.tul.cz/handle/15240/31817 | |
dc.identifier.uri | https://www.sciencedirect.com/science/article/pii/S0168900217301936?via%3Dihub | |
dc.language.iso | eng | cs |
dc.publisher | ELSEVIER SCIENCE BV | cs |
dc.relation.ispartof | Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment | |
dc.relation.ispartofseries | 0 | cs |
dc.relation.uri | https://api.elsevier.com/content/article/eid/1-s2.0-S0168900217301936 | cs |
dc.subject | COMPASS | cs |
dc.subject | CsI | cs |
dc.subject | MPGD | cs |
dc.subject | RICH | cs |
dc.subject | THGEM | cs |
dc.title | The MPGD-based photon detectors for the upgrade of COMPASS RICH-1 | cs |
local.citation.epage | 96-100 | cs |
local.citation.spage | 96-100 | cs |
local.identifier.publikace | 5286 | |
local.identifier.wok | 418267300026 | en |
local.relation.issue | 2 | cs |
local.relation.volume | 876 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- The MPGD-based.pdf
- Size:
- 800.8 KB
- Format:
- Adobe Portable Document Format
- Description:
- článek