A Flexible Array for Cardiac 31P MR Spectroscopy at 7 T

dc.contributor.authorRoat, Sigrun
dc.contributor.authorVít, Martin
dc.contributor.authorWampl, Stefan
dc.contributor.authorSchmid, Albrecht Ingo
dc.contributor.authorLaister, Elmar
dc.date.accessioned2020-05-15T08:47:45Z
dc.date.available2020-05-15T08:47:45Z
dc.date.issued2020-04-15
dc.description.abstractPurpose: The simulation optimization and implementation of a flexible 31P transmit/receive coil array, under the geometrical constraint of fitting into the housing of an already existing 12-channel proton array, to enable localized cardiac 31P MRS at 7 T is presented. Methods: The performance in terms of homogeneity, power and SAR efficiency, and receive benchmark of 32 potential array designs was compared by full wave 3D electromagnetic simulation considering the respective optimal static B+1 shims. The design with the best performance was built and compared to a commercially available single loop in simulation and measurement. Results: Simulation revealed an optimal array design comprising three overlapping elements, each sized 94 × 141 mm2. Simulation comparison with a single loop coil predicted a performance increase due to increased power efficiency and lower SAR values. This was verified by phantom measurements, where an SNR increase of 46% could be observed for localized 31P spectroscopy in a voxel positioned comparable to an in vivo cardiac measurement scenario. Conclusion: A flexible 31P/1H RF coil array with improved SNR is presented, enabling localized in vivo cardiac 31P spectroscopy at 7 T.cs
dc.format.extent10 strancs
dc.identifier.doi10.3389/fphy.2020.00092
dc.identifier.issn2296424X
dc.identifier.urihttps://dspace.tul.cz/handle/15240/154829
dc.identifier.urihttps://www.frontiersin.org/articles/10.3389/fphy.2020.00092/full
dc.language.isocscs
dc.publisherFrontiers Media S.A.
dc.relation.ispartofFrontiers in Physics
dc.subject31P cardiac MRScs
dc.subject3D EM simulationcs
dc.subjectRF coil designcs
dc.subjectultra-high fieldcs
dc.subjectX-nucleuscs
dc.titleA Flexible Array for Cardiac 31P MR Spectroscopy at 7 Tcs
local.accessopen access
local.article.number92
local.identifier.publikace7677
local.relation.volume8
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
A flexible.pdf
Size:
2.37 MB
Format:
Adobe Portable Document Format
Description:
článek
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections