dc.description.abstractThe practical use of Preisach hysteresis model is based on proper identification of weighting function that characterizes the material. Obtaining of the weighting function needs two partial derivations of two-dimensional flux density function, called Everett surface, measured by specific procedure. Since the derivatives require exact measurements, the possible source of errors are studied. Main method is to compare experimental results and simulation. The comparison showed that the excitation current source accuracy influences the quality of Everett surface. Also the numeric integration drift plays an important role. The random or systematic failure in excitation current results in the minor secondary loops on the main hysteresis loop. Simulations of these effects confirmed the predicitons. As practical output it was found that the errors in excitation can be reduced by repeated measurements. The drift can be eliminated, if a more suitable wavefrom is used.en
dc.format.extent6cs
dc.identifier.WebofScienceResearcherIDA-9898-2011 Novák Miroslav
dc.identifier.doi10.1109/ECMSM.2017.7945877
dc.identifier.isbn978-150905582-1cs
dc.identifier.orcid0000-0001-9239-4120 Novák Miroslav
dc.identifier.urihttps://dspace.tul.cz/handle/15240/30858
dc.identifier.urihttps://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=7945877
dc.language.isoengcs
dc.publisherMondragon Unibertsitateko Zerbitzu Editoriala Loramendi kalea,cs
dc.publisher.cityMondragoncs
dc.relation.ispartofseries1cs
dc.relation.urihttp://ieeexplore.ieee.org/stamp/stamp.jsp?arnumber=7945877cs
dc.subjectKeywords&#8211cs
dc.subjectMagnetic hysteresis modelcs
dc.subjectPreisach modelcs
dc.subjectEveret functioncs
dc.subjectFirst Order Reversal Curve methodcs
dc.subjectintegration driftcs
dc.subjectpower voltage source accuracycs
dc.subjectsimulation of disturbancescs
dc.titleDifferences between Preisach Model and Experiment for Soft Ferromagnetic Materials, Effect of Instrument Accuracyen
dc.titleDifferences between Preisach Model and Experiment for Soft Ferromagnetic Materials, Effect of Instrument Accuracycs
local.citation.epage209-214cs
local.citation.spage209-214cs
local.identifier.publikace4310
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Differences between Preisach Model.pdf
Size:
473.88 KB
Format:
Adobe Portable Document Format
Description:
článek
Collections