Analysis of thermal properties, water vapor resistance and radiant heat transmission through different combinations of firefighter protective clothing

dc.contributor.authorNaeem, Jawad
dc.contributor.authorMazari, Adnan
dc.contributor.authorAkcagun, Engin
dc.contributor.authorHavelka, Antonín
dc.contributor.authorKůs, Zdeněk
dc.date.accessioned2019-10-07T07:10:56Z
dc.date.available2019-10-07T07:10:56Z
dc.date.issued2018
dc.description.abstractThis experimental work is an effort to seek the possibility of improvement in thermal protective performance of firefighter protective clothing at different levels of heat flux density. Improvement in thermal protective performance means enhancement in the time of exposure against the heat flux, which will provide extra time to firefighters to perform their duties without suffering from severe injuries. Four different multilayer combinations of firefighter protective clothing were investigated. Each combination consists of outer shell, moisture barrier and thermal liner. Aerogel sheet was also employed as a substitute to thermal barrier. Initially, properties like thermal resistance, thermal conductivity. and water vapor resistance of multilayer fabric assemblies were investigated. Later on these combinations were exposed to different levels of radiant heat flux density i.e. at 10, 20 and 30 kW/m(2) as per ISO 6942 standard. It was noted that those combinations in which aerogel blanket was used as thermal barrier acquire greater thermal resistance, water vapor resistance and have less transmitted heat flux density values.cs
dc.format.extent8 strancs
dc.identifier.urihttps://dspace.tul.cz/handle/15240/153847
dc.identifier.urihttps://www.researchgate.net/publication/331603172_Analysis_of_termal_properties_water_vapor_resistance_and_radiant_heat_transmission_through_different_combinations_of_firefighter_protective_clothing
dc.language.isocscs
dc.publisherINST NATL CERCETARE-DEZVOLTARE TEXTILE PIELARIE-BUCURESTI, STR LUCRETIU PATRASCANU NR 16, SECTOR 3, BUCURESTI, 00000, ROMANIA
dc.relation.ispartofINDUSTRIA TEXTILA
dc.subjectfirefighter protective clothingcs
dc.subjectthermal resistancecs
dc.subjectthermal protective performancecs
dc.subjectheat flux densitycs
dc.titleAnalysis of thermal properties, water vapor resistance and radiant heat transmission through different combinations of firefighter protective clothingcs
local.citation.epage465
local.citation.spage458
local.relation.issue6
local.relation.volume69
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
analzsis of thermal.pdf
Size:
435.39 KB
Format:
Adobe Portable Document Format
Description:
článek
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections