Měření průtoku vody v uzavřeném potrubí
Title Alternative:Water flow measurement in closed pipelines
dc.contributor.advisor | Novotný, Petr | |
dc.contributor.author | Nguyen van, Vu | |
dc.date | 2012 | |
dc.date.accessioned | 2015-07-08 | |
dc.date.available | 2015-07-08 | |
dc.date.committed | 2012-05-25 | |
dc.date.defense | 2012-06-21 | |
dc.date.issued | 2012 | |
dc.date.submitted | 0201-03-06 | |
dc.degree.level | bc | |
dc.description | katedra: KEZ; přílohy: 1 CD; rozsah: 59 stran, Cambira font | cs |
dc.description.abstract | Aim of this bachelor thesis to measure water flow in closed pipelines by using the orifice and mass flow meter, Coriolis mass flow meter from Siemens, and to compare these results. Verify efficiency of electrical pump, which is integrated on closed pipelines, while changing the mass flow. Propose another suitable mass flow meter and manometer for laboratory purposes. Write instruction and protocol for measuring water mass flow with the pipelines. | en |
dc.description.abstract | Cílem této bakalářské práce je měření průtoku na trati pomocí clony a hmotového průtokoměru, Coriolisův průtokoměr firmy Siemens. Nastavit účinný průběh zabudovaná čerpadla na změnění průtoku. Byly porovnány výsledky z měření, navrženy vhodná další měřidla. Vypracovat návod a protokol pro účely technického měření. | cs |
dc.format | text | |
dc.identifier.uri | https://dspace.tul.cz/handle/15240/12733 | |
dc.language.iso | cs | |
dc.publisher | Technická Univerzita v Liberci | cs |
dc.subject | - flow meter | en |
dc.subject | - mass flow meter | en |
dc.subject | - volumetric flow meter | en |
dc.subject | - coriolis flow meter | en |
dc.subject | - orifice | en |
dc.subject | - mass flow in pipelines | en |
dc.subject | - realistic assessment | en |
dc.subject | - reliability | en |
dc.subject | - measurement procedure | en |
dc.subject | - průtokoměr | cs |
dc.subject | - hmotnostní průtokoměr | cs |
dc.subject | - objemový průtokoměr | cs |
dc.subject | - coriolisův průtokoměr | cs |
dc.subject | - clona | cs |
dc.subject | - průtok v uzavřeném potrubí | cs |
dc.subject | - přesnost | cs |
dc.subject | - spolehlivost | cs |
dc.subject | - postup měření | cs |
dc.subject.verbis | průtokoměry | cs |
dc.title | Měření průtoku vody v uzavřeném potrubí | cs |
dc.title.alternative | Water flow measurement in closed pipelines | en |
dc.type | Thesis | |
local.department | KEZ | cs |
local.faculty | Fakulta strojní | cs |
local.identifier.stag | 24562 | |
local.identifier.verbis | 464285 | |
local.note.administrators | oprava_A | |
local.verbis.aktualizace | 2019-10-05 05:45:22 | cs |
local.verbis.studijniprogram | KEZ Strojírenství/Stroje a zařízení | cs |
Files
Original bundle
1 - 4 of 4
Loading...
- Name:
- bc_24562.pdf
- Size:
- 2.43 MB
- Format:
- Adobe Portable Document Format
- Description:
- kvalifikační práce
Loading...
- Name:
- opo_24562.pdf
- Size:
- 135.25 KB
- Format:
- Adobe Portable Document Format
- Description:
- posudek oponenta
Loading...
- Name:
- ved_24562.pdf
- Size:
- 78.24 KB
- Format:
- Adobe Portable Document Format
- Description:
- posudek vedoucího
Loading...
- Name:
- obh_24562.pdf
- Size:
- 196.28 KB
- Format:
- Adobe Portable Document Format
- Description:
- výsledek obhajoby