Influence of carbon coatings origin on the properties important for biomedical application

dc.contributor.authorMitura, StanisŁaw
dc.contributor.authorNiedzielski, Piotr
dc.contributor.authorJachowicz, Dariusz
dc.contributor.authorLanger, Małgorzata A.
dc.contributor.authorMarciniak, Jan
dc.contributor.authorStanishevsky, Andrei Vladimirovich
dc.contributor.authorTochitsky, Eduard I.
dc.contributor.authorLouda, Petr
dc.contributor.authorCouvrat, Patrice
dc.contributor.authorDenis, Michel
dc.contributor.authorLourdin, Pierre
dc.date.accessioned2016-07-08
dc.date.available2016-07-08
dc.date.issued1996
dc.description.abstractThe purpose of the present study was to investigate the properties of a carbon layer depending of the origin of applied methods. Quasiamorphous carbon coatings prepared by ion beam methane decomposition by RF dense plasma and vacuum pulsed arc deposition were applied to stainless steel implants used in surgery. The studies of carbon films as coatings for implants in surgery were aimed on the investigations of biological resistance of implants, histopathological investigations using laboratory animals, tests of corrosion resistance, measurements of mechanical properties and a breakdown test in Tyrod solution. The comparison of the properties of the coating produced by these methods shows very good biotolerance and biocompatibility of all of the coatings. They are not corroded in physiological fluids. From the other side they have different properties, especially electrical and optical, and are not influenced on medical applications. The obtained results prove that the implants coated by all the methods mentioned are a very good material for medical use.en
dc.formattext
dc.identifier.doi10.1016/0925-9635(95)00525-0
dc.identifier.issn0925-9635
dc.identifier.scopus2-s2.0-0001086783
dc.identifier.urihttps://dspace.tul.cz/handle/15240/16634
dc.identifier.urihttps://www.sciencedirect.com/science/article/abs/pii/0925963595005250?via%3Dihub
dc.language.isoen
dc.relation.ispartofDiamond and Related Materials
dc.sourcej-scopus
dc.sourcej-wok
dc.subjectbiomaterialsen
dc.subjectcarbon coatingsen
dc.subjectPlasma assisted CVDen
dc.titleInfluence of carbon coatings origin on the properties important for biomedical applicationen
dc.typearticle
local.accessaccess
local.citation.epage1188
local.citation.spage1185
local.departmentDepartment of Material Science
local.facultyFaculty of Mechanical Engineering
local.identifier.codenDRMTE
local.identifier.wokA1996VH52700018
local.notenefunguje RIV
local.relation.issue10
local.relation.volume5
Files
Collections