Sample pretreatment in determination of anions in mine waters with high Iron contents

Title Alternative:Úprava vzorku pro stanovení aniontů v důlní vodě s vysokým obsahem železa
dc.contributor.authorKuráň, Pavel
dc.contributor.authorČmelík, Jiří
dc.contributor.authorPilařová, Vera
dc.contributor.authorKrejčová, Michaela
dc.contributor.authorJanoš, Pavel
dc.contributor.authorKuráň, Pavel
dc.contributor.authorČmelík, Jiří
dc.contributor.authorPilařová, Vera
dc.contributor.authorKrejčová, Michaela
dc.contributor.authorJanoš, Pavel
dc.date.accessioned2016-05-24
dc.date.available2016-05-24
dc.date.issued2013
dc.description.abstractReliable analysis of anions in mine waters with high iron and sulfate contents is important for their characterization. However, both traditional and LC methods failed in direct anion analysis. The article describes two sample pretreatments - alkalization and cation exchange. The pretreated water samples were analyzed by potentiometric titration, spectrophotometry, ion chromatography with conductivity detector in suppressed regime and HPLC with diode array detector using indirect UV detection at 260 nm. Both the sample pretreatments enable determination of some anions, the former procedure being more suitable for the purpose. Potentiometric titration and spectrophotometry seem to be the most suitable due to low detection limits for all the selected anions ranging from 0.4 to 1.8 mg l-1. The application of ion chromatography and liquid chromatography with diode array detector for the purpose is also possible. However, due to very high detection limits of samples pretreated by cation exchange (26-121 mg l-1) and low recoveries of samples pretreated by alkalization (<17 %) for all the selected anions, HPLC-DAD is not suitable for analysis of real samples. Validation and analytical characteristics of the methods are given and discussed.en
dc.formattext
dc.identifier.issn0009-2770
dc.identifier.scopus2-s2.0-84878677278
dc.identifier.urihttps://dspace.tul.cz/handle/15240/16399
dc.identifier.urihttp://www.chemicke-listy.cz/docs/full/2013_05_381-385.pdf
dc.language.isoen
dc.language.isocs
dc.publisherTechnická Univerzita v Libercics
dc.publisherTechnical university of Liberec, Czech Republicen
dc.relation.ispartofChemické Listycs
dc.sourcej-scopus
dc.sourcej-wok
dc.titleSample pretreatment in determination of anions in mine waters with high Iron contentsen
dc.title.alternativeÚprava vzorku pro stanovení aniontů v důlní vodě s vysokým obsahem železacs
dc.typeArticle
local.accessopen
local.citation.epage385
local.citation.spage381
local.departmentInstitute of Novel Technologies and Applied Informatics
local.facultyFaculty of Mechatronics, Informatics and Interdisciplinary Studies
local.facultyFaculty of Mechatronics, Informatics and Interdisciplinary Studies
local.fulltextyes
local.identifier.codenCHLSA
local.identifier.stagRIV/44555601:13520/13:43885375
local.identifier.wok324159200008
local.relation.issue5