Biomechanická analýza explantovaných prsních implantátů při nárazových testech v laboratorních podmínkách
| dc.contributor.advisor | Richter Aleš, prof. Ing. CSc. :54924 | cs |
| dc.contributor.author | Dymešová, Tereza | cs |
| dc.contributor.other | Mazač Martin, Ing. Ph.D.;Mašková Barbora, Ing. Ph.D. :66982;67707 | cs |
| dc.contributor.referee | Gejdošová Ivana, Ing. :65139 | cs |
| dc.date.accessioned | 2025-07-14T10:46:18Z | |
| dc.date.available | 2025-07-14T10:46:18Z | |
| dc.date.committed | 2.7.2025 | cs |
| dc.date.defense | 23.6.2025 | cs |
| dc.date.issued | 2025-06-23 | cs |
| dc.date.submitted | 12.11.2024 | cs |
| dc.description.abstract | Mnoho žen se trápí sníženým sebevědomím z důvodu nevyhovující velikosti nebo tvaru svého poprsí. Augmentace je chirurgický zákrok, který pomáhá dosáhnout psychického komfortu. Prsní implantáty se zavádějí nejen z estetických příčin, ale například i po mastektomii z důvodu prodělaného onkologického onemocnění. Ačkoliv se jedná o běžný zákrok, jsou s ním spojeny i nežádoucí komplikace. Velmi častou komplikací vyskytující se u prsních implantátů je ruptura, ke které dochází v důsledku různých vnějších mechanických vlivů, jako jsou nárazy, tlak, poškození ostrými předměty nebo dlouhodobé namáhání. Testování těchto vlivů je nezbytné pro zajištění vývoje bezpečnějších materiálů, což vede k jejich spolehlivému používání a dlouhodobé životnosti. Primárním cílem práce byl rozbor biomechanických zkoušek dostupných v laboratoři, na jehož základě byly zrealizovány nárazové testy na explantovaných prsních implantátech. Experiment byl proveden v laboratoři Technické univerzity v Liberci. K nárazovým testům byly použity vzorky prsních implantátů o různých objemech, pro navazující testování byl jeden ze vzorků úmyslně poškozen skalpelem. Každý vzorek byl vystaven nárazům tenisovým míčkem letícím rychlostí 50 km/h. K vystřelování míčku byl použit lineární hydromotor. Celý proces byl natáčen na vysokorychlostní kameru. Výsledky testů ukázaly, že opakované nárazy rychlostí zmíněnou výše nemusí nutně vést k poškození struktury obalu prsního implantátu. Jakmile byl ale prsní implantát poškozen skalpelem a vystaven stejným nárazům, objevily se jasné známky šíření ruptury v podélném i příčném směru a zároveň únik gelu z prsního implantátu. | cs |
| dc.description.abstract | Many women struggle with lowered self - esteem due to the inadequate size or shape of their breasts. Augmentation is a surgical procedure that contributes to better psychological comfort. Breasts implants are inserted not only for aesthetic reasons, but also for example, after a mastectomy due to cancer. Although this is a common procedure, there are also unwanted complications associated with it. A very common complication with breast implants is rupture, which occurs due to various external mechanical influences such as impact, pressure, damage with sharp objects or prolonged stress. Testing for these effects is essential to ensure the development of safer materials, leading to reliable use and long life. The primary objective of this work was to analyse the biomechanical tests available in the laboratory, based on which impact tests were implemented on explanted breast implants. The experiment was carrried out in the laboratory on Technical university of Liberec. Three breast implant specimens of different volumes were used for the impact tests and one of the specimens was intentionally damaged with a scalpel for follow-up testing. Each specimen was subjected to impact with a tennis ball flying at 50 km/h. A linear hydraulic motor was used to eject the ball. The entire process was filmed on a high-speed camera. The test results showed that repeated impacts at the speed mentioned above do not necessarily lead to damage to the structure of the breast implant. Once the breast implant was damaged by the scalpel and was exposed to the same impacts, there were clear signs of rupture spreading in both the longitudinal and transverse directions a at the same time gel leakage from the breast implant. | en |
| dc.format | 73 s. | cs |
| dc.identifier.uri | https://dspace.tul.cz/handle/15240/177006 | |
| dc.language.iso | CS | cs |
| dc.subject | Biomechanická analýza | cs |
| dc.subject | prsní implantáty | cs |
| dc.subject | nárazové testy | cs |
| dc.subject | ruptura | cs |
| dc.title | Biomechanická analýza explantovaných prsních implantátů při nárazových testech v laboratorních podmínkách | cs |
| dc.title | Biomechanical analysis of explanted breast implants during impact testing in laboratory conditions | en |
| dc.type | diplomová práce | cs |
| local.degree.abbreviation | Navazující | cs |
| local.identifier.author | D23000139 | cs |
| local.identifier.stag | 48501 | cs |
Files
Original bundle
1 - 4 of 4
Loading...
- Name:
- DP_Dymešová.pdf
- Size:
- 2.98 MB
- Format:
- Adobe Portable Document Format
- Description:
- VŠKP ( 28.4.2025 20:56 )
Loading...
- Name:
- posudek-richter-dp-dymešová.pdf
- Size:
- 141.51 KB
- Format:
- Adobe Portable Document Format
- Description:
- Posudek vedoucího VŠKP ( 15.5.2025 8:08 )
Loading...
- Name:
- Posudek oponenta dp_Dymešová.pdf
- Size:
- 142.55 KB
- Format:
- Adobe Portable Document Format
- Description:
- Posudek oponenta VŠKP ( 3.6.2025 12:46 )
Loading...
- Name:
- ProtokolSPrubehemObhajobySTAG.pdf
- Size:
- 39.38 KB
- Format:
- Adobe Portable Document Format
- Description:
- Průběh obhajoby VŠKP ( 23.6.2025 11:50 )